Unitherm Insulation Systems

  • Home
  • Shop
  • Insulation Solutions
    • Plastics Equipment Insulation
    • Pipe and Valve Insulation
    • Passive Fire Protection
    • Freeze Protection and Material Handling
    • Exhaust Insulation
    • Marine Exhaust Insulation
    • Rigid Board Insulation
    • OEM
  • Applications
    • Aerospace
    • Data Centers
    • Defense
    • Exhaust Systems
    • Gas Compressors
    • Locomotive
    • Marine
    • Oil and Gas
    • On Highway
    • Power Generation
    • Reciprocating Engines
    • Turbines
  • Services and Capabilities
    • Custom Insulation Blankets, Jackets, and Covers
    • 3D AutoCAD
    • High Temperature Raw Goods
    • Custom Embroidery
    • WaterJet/CNC Machining
    • Private Labeling
  • Reseller Program
    • Reseller Locator
  • Blog
  • About
    • Contact
    • News
    • Customer Service
    • Order Now
  • Media
    • Documents
    • MSDS Sheets
    • Product Literature
    • Product Gallery
    • Video
    • Energy Study Library
    • New Customer Form
  • NPE 2027

November 17, 2026 by UniAdmin

Why Valves Need Special Attention in Freeze Protection

A freeze-protection system isn’t made entirely of straight pipe. Valves, pumps, fittings, supports, and other components must be considered as part of the thermal system — and they’re often where freeze-protection designs fall short.

Heat-tracing manufacturers explicitly account for this. Unitherm International’s design procedure requires designers to identify the type and number of valves, pumps, other equipment, and pipe supports. When determining total heating-cable length, allowances are then added for these components.

Why Can’t Engineers Just Calculate the Straight Pipe?

Because equipment and penetrations can change the heat-loss characteristics of the system, heat sinks penetrating insulation surfaces can complicate pipe-tracing heat-load calculations.

That means an otherwise well-designed straight run doesn’t automatically account for every component connected to it. Valves and fittings have irregular shapes, more surface area relative to volume, and often more exposed metal — all of which change how quickly they lose heat compared to a straight, uniformly insulated pipe.

Insulation Should Continue Across Fittings

ASHRAE’s mechanical insulation guidance states that fittings — including valves, tees, crosses, and elbows — can use preformed fitting insulation, fabricated insulation, sectional insulation pieces, or insulating cements.

Importantly, ASHRAE states that fitting insulation should provide thermal performance equal to that of the sectional pipe insulation. In other words, the thermal envelope shouldn’t simply stop when the piping reaches a valve.

Where FreezePro Valve Jackets Fit

UniTherm’s FreezePro Valve Insulation Jackets are designed specifically for complex shapes such as valve fittings, strainers, and T- or Y-joints. FreezePro is an electrically heated insulation system rather than passive insulation alone — UniTherm describes the system as providing directional heat to temperature-sensitive equipment while combining heating and insulation in a removable jacket.

FreezePro valve products are listed for applications including globe, needle, gate, ball, plug, butterfly, diaphragm, and check valves, as well as fittings, pumps, manifolds, filters, regulators, and other equipment.

Design the Whole System, Not Just the Straight Pipe

The engineering lesson isn’t that every valve requires the same product. It’s that valves and other components need to be included in the freeze-protection design instead of treating the straight pipe as the entire system.

If your freeze-protection plan stops at the valves, strainers, or manifolds on your line, UniTherm can help you close that gap with FreezePro Valve Insulation Jackets and the right heat-tracing approach for the rest of the system. Contact our team to talk through your equipment.


This is week 8 of a 10 week series discussing the methods and science of frost protection systems. To learn more or to follow this series click this link: Subscribe to Updates

To find out more information on the frost protection offerings that Unitherm International can provide, go to shop.unitherm.com to view our full listing of products or email quote@unitherm.com to speak to a representative about custom solutions.

Filed Under: Freeze Protection Tagged With: freeze protection for fittings, FreezePro valve jacket, heat trace valves, valve freeze protection, valve insulation jacket

  • Español

Quick Links

MSDS
Product Brochures
Energy Study Library
Product Videos

Follow UniTherm

Facebook
Twitter
Blog
YouTube
Instagram
Pinterest

UniTherm Insulation Systems

711 Jones St.
Lewisville, TX 75057
Toll Free: 800.657.9542
Phone: 972.436.1401
Fax: 972.436.0112
info@unitherm.com

Copyright © 2026 · Executive Pro Theme on Genesis Framework · WordPress · Log in